AUTOCLAVE HV 110 HIRAYAMA
Description

Space-saving design with lid opening upward. Programmable auto-start for initiating a cycle up to 1 week later. Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97°C. Automatic air purging by a microprocessor prevents over-pressurization during a cycle. One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust. Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly. In-process display shows status and progress of sterilization cycle. Agar sterilization modefor sterilizing agar and then automatically maintaining it at liquid temperature. Unique accessory: Floating sensor to monitor load temperature. Sterilization timer is activated only when load temperature reaches set temperature. Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up

Other Info

Specifications MODEL : HV-110 TEMPERATURE Operating Range : 105ºC to 135ºC Display Range : 137ºC Warming Range : 45ºC to 60ºC Agar Dissolution : Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC (programmable for up to 20 hours to prevent coagulations) GAUGE PRESSURE Operating Range : 3 to 30 psi (0.021 to 0.206MPa) Maximum Allowable : 38 psi ( 0.26MPa) TIMER Sterilization : 1 to 250 minutes Delayed Auto-start : Program autoclave to start 1 minute to 7 days later DIMENSIONS Overall (W x D x H) : 26.0" x 25.6" x 46.5" (66 cm x 65 cm x 118 cm) Chamber : 110 liters (Diameter x Height) 16.5" x 31.3" (42.0 cm x 79.5 cm) SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Warming -> Completion 2. For liquids Heating -> Sterilization -> Exhaust (from no exhaust to slow, programmable) -> Completion 3. For solids Heating -> Sterilization -> Exhaust (fast, default) -> Completion 4. For melting agar or for faster start-up Rapid melting at 60°C to 100°C (temperature and time programmable) -> Maintain at 45°C to 60°C (temperature programmable) -> Completion ACCESSORIES Wire basket,Exhaust bottle, Heater cover,drain hose 50cm, Exhaust hose 50cm, drain bottle, Strap, Operation manual and Caster stoppers.

Equipment Use

Teaching and research laboratories


Manufacturer
HIRAYAMA MANUFACTURING CORP.
Brand
HIRAYAMA
Model
HV 110
Year Manufactured
Year Procured
2004
Department
PUSAT PENGAJIAN SAINS KESIHATAN
Location
Ppsk-blok A > G > Upms > Bilik 9

Category
Function
Category
Staff operated
Equipment Status
Good